Skip to main content

Table 3 Analysis of variance results comparing laser and cautery particle counts

From: ‘The air that we breathe’: assessment of laser and electrosurgical dissection devices on operating theater air quality

Metric

Location

Laser median

Cautery median

ANOVA results

PM2.5 (μg/m3)

Hallway

2.00

2.00

P < 0.05

OR

3.00

2.00

P < 0.05

Roof

23.0

22.0

P > 0.05

UFPs (particle #/cm3)

Hallway

564

668

P > 0.05

OR

462

798

P < 0.05

Roof

14105

11646

P > 0.05

Fine particle number count (particle #/cm3)

Hallway

0.45

0.42

P > 0.05

OR

0.43

0.32

P < 0.05

Roof

14.53

2.17

P < 0.05

Coarse particle number count (particle #/cm3)

Hallway

0.07

0.06

P < 0.05

OR

0.04

0.03

P < 0.05

Roof

0.60

0.13

P < 0.05

  1. PM = particulate matter, UFP = ultrafine particle.